Functional Descriptions (By Parameter No.)

BIAS/GAIN FUNCTION SELECT, BIAS FREQUENCY, GAIN FREQUENCY (Parameter Nos. 56, 57 & 58)

The relation with the output frequency and frequency setting signal (potentiometer, 0 to 5V, 0 to 10V, 4 to 20mA), can be changed randomly. Use this function according to the application.

(Parameter No. 56 : BIAS/GAIN FUNCTION SELECT)

Data setting range (Hz) Function details
0 Bias/gain function disabled
1 Bias/gain function enabled

(Parameter No. 57 : BIAS FREQUENCY setting)

Data setting range (Hz) - 99.9 to 400 (0.1 units)

(Parameter No. 58 : GAIN FREQUENCY setting)

Data setting range (Hz) 0000 and 0.2 to 400 (0.01 units)

(When "0000" is set, OV stop will function.)

Notes)

1. A frequency exceeding the maximum output frequency or upper frequency clamp cannot be output. The frequency will not drop below the lower frequency clamp.

2. Even if a minus frequency setting signal is input, the inverter will not run in reverse.